• Gtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile Measurement
  • Gtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile Measurement
  • Gtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile Measurement
  • Gtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile Measurement
  • Gtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile Measurement
  • Gtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile Measurement

Gtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile Measurement

Warranty: One Year
Transport Package: Standard Export Package
Specification: 300*200*55mm
Origin: China
Gold Member Since 2024

Suppliers with verified business licenses

Guangxi, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 4 staff(s) with over 6 years of overseas trading experience
In-stock Capacity
The supplier has In-stock capacity
to see all verified strength labels (12)

Basic Info.

Model NO.
GTJ-U920

Product Description

 
Gtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile Measurement

Instrument introduction

The Concrete Ultrasonic Detector is an intelligent instrument for non-destructive testing ofnon-metallic materials and components such as concrete, rock, ceramics, graphite.plastics, etcusing ultrasonic pulse detection technology.it combines ultrasonictransmission, dual-channel synchronous reception, high-speed digital signal acquisitionautomatic measurement of acoustic parameters, digital analysis processing, real-timedisplay of results, digital storage and output it can be used for concrete pile integritytesting, strength testing, structural internal defect detection and crack detection.The GTJ-U900 Concrete Uitrasonic Detector inciudes the following functional modules.
(1) Sound wave transmission method to detect the integrily of the pile (referred to as"measuring pile");
(2)Ultrasonic method is not dense and cavity detectlon (referred to as "measurement");
(3)Ultrasonicrebound comprehensive method for testing concrete strength (referred to as"measured strength");
(4)Uitrasonic fat test method for detecting concretecrack depth (referred to as"'sampling");


Relevant testing procedures
(1)"Uitrasonic Method for Testing Concrete Defects" -CECS 21:000
(2)Technical specification for Uitrasonic Rebound Comprehensive Method for TestingConcrete strength-CECS 02.2005
(3)"Code for Testing Concrete Strength of Railway Engineering Structures"-TB10426-2004
(4)Technical Regulations for Concrete Structure Detection of Water Transportation Engineering-JTs 239-2015Strength
(5)"Technical RequlationsforStrengthTestingofHighConcrete"JGJ/T294-2013
(6)Technical $pecifcations for Rebound Method and Uitrasonic Rebound ComprehensiveMethod for Testing Pumped Concrete Strength-DBJ/T01-78-2003
(7)Technical Specification for Uitrasonic Rebound Comprehensive Method for Testing Concrete strength-DB37/T2361-2013"TechnicalRegulationsTestingConcreteCompressive
(8)forstrength"-DG/TJ08-2020-2007
(9)Technical Speciication for Ultrasonic Rebound Comprehensive Method for TestingConcrete strength-DBJ53/T-53-2013
(10)Technical Specification for Uitrasonic Rebound Comprehensive Method for TestingConcrete Strength of Highway Engineering-DB51/T1996-2015
(11)"Technical Specifcations for Building Pile Testing" JGJ 106-2014
(12)"Technical Regulations for Dynamic Testing of Foundation Piles in HighwayEngineering"-JTG/T F81-01-2004(13)"Technical Regulations for Testing Pile Foundations of Railway Engineering"-TB10218-2008
(14)"Code for Bullding Foundatilon Testing"-DBJ 15-60-2008
(15)"shenzhen Building Pile Testing Procedures"-SJG09-2015(16)"Technical Specifications for Building Pile Testing"-DGJ08-218-2003


Main performance indicators
Gtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile Measurement
Precautions

(1)Avoid water ingress,
(2)Avoid high temperature (>50°C);
(3)Avoid close to strong magnetic felds, such as large electromagnets, largetransformers, etc.,
(4)to avoid the violent impact ofthe transducer
(5)The necessary protective measures should be taken when using in humid, dusty orcorrosive gas environment,
(6)The instrument should be stored in a ventilated, cool, dry place,
(7) When the instrument is not used for a long time, the rechargeable battery will naturallydischarge, resulting in a decrease in power. it is recommended to recharge before use,
(8)Do not open the instrument case without permission.
(9) Please connect the signal line and the transducer in the offstate, and pay attention toconfirm the order of the plane transducer receiving and transmitting lines to avoid thewrong insertion.

Gtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile MeasurementGtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile MeasurementGtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile MeasurementGtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile MeasurementGtj-U920 Non-Metallic Ultrasonic Detector Automatic Pile Measurement

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.