Gas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene Oxide

Product Details
Appliance: Biochemistry
Mobile Phase: Gas
Chromatography Type: Gas Chromatography
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 5 foreign trading staff(s) and 4 staff(s) with over 6 years of overseas trading experience
In-stock Capacity
The supplier has In-stock capacity
to see all verified strength labels (12)
  • Gas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene Oxide
  • Gas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene Oxide
  • Gas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene Oxide
  • Gas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene Oxide
  • Gas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene Oxide
  • Gas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene Oxide
Find Similar Products

Basic Info.

Model NO.
GC126N
Baseline Noise
≤ 0.06mv
Transport Package
Standard Export Package
Origin
China

Product Description

Gas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene Oxide
Gas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene OxideGas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene OxideGas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene OxideGas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene OxideGas Chromatograph Thermal Conductivity Detector Residual Detection of Ethylene Oxide
Technical features:
The host adopts a 7-inch color touch screen, with a user-friendly human-machine exchange interface.
The computer reverse control and the host touch screen achieve synchronous bidirectional control.
A multi-core, 32-bit embedded hardware system ensures the reliable operation of the instrument.
Digital display of carrier gas/hydrogen/air flow rate (pressure).
Equipped with air shortage alarm protection function; Heating control protection function (when the column box door is opened during use, the column box fan motor and heating system will automatically shut down).
The split flow rate/split ratio can be automatically controlled to save carrier gas.
Configure the installation and positioning interface of the automatic sampler, and match it with various specifications of automatic samplers.
The data collection is equipped with a standard dual channel data acquisition card, with a sampling time of 50ms.
Using a logarithmic amplification board, the detection signal has no cut-off value, and the synchronous external trigger function can be used to start both the host and workstation simultaneously by external signals (such as automatic samplers, thermal analyzers, etc.).
Equipped with comprehensive system self inspection function and automatic fault identification function.
It has an extended functional interface with 8 external events, and can be equipped with various control valves to work according to its own set timing.
The external connection method is through Ethernet port connection (RJ45), providing convenience for remote control of data.
In addition to the independent heating zone of the column box, there are also 6 heating zones. Two heating zones for injection ports, two heating zones for detectors, and two auxiliary heating zones.
The maximum operating temperature of the auxiliary heating zone can reach 400 ºC


Column temperature box:
Temperature range: 5 ºC~400 ºC above room temperature
Temperature control accuracy: ± 0.1 ºC
Program heating up: 9th order/10th platform
Total program time: 9999.9 minutes
Maximum heating rate: 60 ºC/min


Detector:
Install up to 2 units simultaneously (FID, TCD, ECD, FPD, NPD)
The flow rate/pressure is displayed directly on the screen.
Temperature setting: maximum 400 ºC
Hydrogen flame ionization detector (FID):
High voltage switch control: automatic control
Baseline signal display: digital display
Ignition coil control: automatic ignition
Detection limit: ≤ 3 × 10-12 g/s
Sample: n-hexadecane (minimum detection limit: 3pg/s)
Dynamic range: 107
Thermal conductivity detector (TCD):
Bridge voltage switch control bridge current setting: 0~220 mA
Sensitivity: ≥ 5000 mV · mL/mg
Dynamic range: 105
Baseline noise: ≤ 0.06mV
Electronic Capture Detector (ECD):
Radiation source: Ni63
Detection limit: ≤ 8 × 10-14 g/s
Sample: r 666 (minimum detection amount: 80fg/s)
Dynamic range: 10
Flame Photometric Detector (FPD):
Temperature setting: maximum 400 ºC
Detection limit: ≤ 2 × 10-12 g/s (P)
≤ 4 × 10-11 g/s (S)
Sample: Methyl parathion
Dynamic range: P 10 3 S 10 2

 

Send your message to this supplier